Hollow-Shaft Frameless Torque Motor Selection: Don’t Simply Match Nameplate Ratings—Work Out Three Key Calculations First
You are here: Home » Blog » Blog » Industry Information » Hollow-Shaft Frameless Torque Motor Selection: Don’t Simply Match Nameplate Ratings—Work Out Three Key Calculations First

Hollow-Shaft Frameless Torque Motor Selection: Don’t Simply Match Nameplate Ratings—Work Out Three Key Calculations First

Views: 0     Author: Site Editor     Publish Time: 2026-11-27      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button

If you are selecting a motor for a collaborative robot, a humanoid joint, or a precision rotary stage, you have probably noticed a pattern: in almost every published joint cross-section, there is no traditional servo motor housing or output shaft to be found. The stator and rotor are embedded directly into the structure like two thin discs, with a hollow cavity in the middle for routing cables, passing a shaft, or mounting an encoder. This is the practical background behind why hollow-shaft frameless torque motors have become the “default answer” for joints.

精密机械轴承环组件】【。.png

But “default” does not mean “choose casually.” A frameless motor has no housing, bearings, or shaft of its own, so its selection logic is fundamentally different from that of a housed servo. The numbers in a manufacturer’s datasheet are measured on the manufacturer’s test bench under specific mounting and cooling conditions; the thermal resistance, assembly coaxiality, and bus voltage inside your joint are all things you have to manage yourself. Taking nameplate ratings at face value is the most common starting point for selection failures.

First Calculation: Torque—Continuous and Peak Are Two Completely Different Capabilities

Frameless motor datasheets usually provide two torque numbers: continuous torque and peak torque. Their physical meanings are fundamentally different, and they correspond to different operating scenarios.

Continuous torque is the torque the motor can output continuously over the long term under specified cooling conditions, with the winding temperature not exceeding the limit allowed by its insulation class. It measures “whether the motor can keep running indefinitely.” Peak torque, by contrast, is the upper limit the motor can reach for a short time—usually on the order of seconds—for acceleration, impact, or temporary overload. As it approaches peak torque, the iron core begins to saturate, and the proportional relationship between torque and current deviates noticeably.

The most common selection mistake is to use peak torque against the continuous load requirement, or conversely, to use continuous torque to check the acceleration phase. The correct approach is to work backward from the joint output. Let the required continuous torque at the joint output be Tout, the gear ratio be i, and the reducer efficiency be η. Then the required continuous torque on the motor side is:

image.png

When load torque varies with time, the RMS torque Trms must also be compared with the motor’s continuous torque, and the maximum instantaneous torque in the cycle must be compared with the peak torque.

Here is a hard constraint from engineering practice: it is recommended to leave more than 30% margin on continuous torque. The continuous torque in a manufacturer datasheet is obtained on a test bench with the lowest possible thermal resistance. In your joint, the contact thermal resistance after the stator is pressed into the housing, along with thermal coupling from the surrounding reducer and encoder, will make the actual cooling conditions worse. If you select based on the manufacturer’s ideal value, it may run for a short time, but after half an hour of continuous operation it may trigger thermal protection.

There is another detail that is easy to overlook: the hollow structure of a hollow-shaft motor changes the stiffness distribution of the rotor. At the same outer diameter, the larger the hollow bore, the thinner the rotor yoke wall, and the lower the torsional stiffness. For applications requiring high dynamic response or high control bandwidth, you should confirm with the manufacturer how the hollow bore size affects rotor stiffness during selection—do not look only at the torque number.

Second Calculation: Thermal—The “Rating” of a Frameless Motor Is Defined by You

A housed servo motor comes with its own housing and fan, and its heat dissipation path is packaged. Once a frameless motor has its housing stripped away, the entire machine structure becomes its heat sink. The surface where the stator is pressed against the joint housing is the most critical bottleneck in the entire thermal path.

Winding temperature rise can be estimated with a very simple thermal circuit model:

image.png

Here Ploss is mainly copper loss (I²R), and Rth,interface is the contact thermal resistance between the stator and the housing. For a frameless motor with an outer diameter on the order of 60 mm, the total thermal resistance from winding to ambient may be around 1.5 °C/W. If the joint housing is aluminum alloy and water-cooled, this value can be lower; if it relies only on natural convection, the thermal resistance will rise significantly.

The bottom line for thermal verification is insulation class. Under the framework of IEC 60034-1, the allowable temperature rise limits differ by insulation class: Class B is about 130 K, Class F about 155 K, and Class H about 180 K (based on a 40 °C ambient temperature). But there is a failure mode that occurs earlier than insulation failure: permanent magnet demagnetization. Once NdFeB magnets exceed their maximum operating temperature, irreversible demagnetization permanently weakens torque output. During selection, two boundaries must be confirmed at the same time: the allowable temperature rise limit of the winding insulation and the allowable maximum temperature of the magnets—take the stricter of the two.

For continuously running joints, steady-state thermal resistance determines “whether it can run continuously”; for frequent start-stop or burst motions, heat capacity and transient temperature rise determine “how long it can last for a burst.” Only by substituting the real motion profile—rather than a single operating point—into the thermal model can you judge whether the continuous torque margin is sufficient.

Third Calculation: Voltage—The Root Cause of “Mushy” Torque at High Speed

Normal output at low speed, then torque drops sharply after speed reaches 60–70% of the design value, and the drive reports overcurrent or overvoltage—this is a very typical phenomenon during frameless motor commissioning. The root cause is often not the motor itself, but insufficient bus voltage.

When the motor rotates, it generates back EMF, whose magnitude is proportional to speed and the back EMF constant Ke. For the drive to force current into the windings, the bus voltage must overcome both the back EMF and the resistive voltage drop:

image.png

In actual selection, a margin of at least 1.15× should be left on the result. If the joint’s maximum speed requirement corresponds to a high Ke*w, and the bus voltage margin is insufficient, the current loop will enter saturation, and the actual torque that can be output at high speed will be far below expectations. In this case, choosing a lower-Ke winding variant is a more fundamental solution than “opening up the current limit”—the latter only fools the alarm; the motor still has no torque at high speed.

The hollow-shaft structure has an indirect effect here: a hollow shaft is often used for routing cables or mounting an output-end encoder, which changes the axial length constraint of the joint and thus affects your choice of motor stack length L. The torque of a frameless motor roughly follows the relationship

image.png

: doubling the diameter quadruples the torque, and doubling the length doubles the torque. When axial space is limited and a thin-stack motor must be selected, pay particular attention to matching Ke with the maximum speed; otherwise, the voltage limit of a thin motor may be reached before its torque limit.

Integration Pitfalls Specific to Hollow-Shaft Motors: Coaxiality, Encoders, and Assembly

Once the three calculations above are clear, the general direction of electromagnetic and thermal performance is set. However, a large share of hollow-shaft frameless motor failures do not come from electromagnetic design, but from integration.

Coaxiality is the number-one killer. The air gap of a frameless motor is only on the order of a millimeter or even smaller. The stator and rotor are mounted on the joint housing and the reducer input side, respectively, and the coaxiality between them is guaranteed entirely by your machining and assembly tolerances. Excessive coaxiality error directly causes uneven air gap and increased unbalanced magnetic pull—at best, torque ripple and noise; at worst, stator-rotor rubbing and failure. One of the most common causes of frameless motor failure in the industry is inadequate coaxiality control. For batch assembly, it is recommended to use a non-magnetic guide shaft together with a press, with a force sensor monitoring the pressing process, to avoid introducing tilt through manual hammering.

An encoder is not something you can simply “bolt on.” Hollow shafts are often used to place the output-end encoder or route cables inside the motor’s hollow area, but the mounting rigidity of the encoder directly determines low-speed performance. Any slight relative looseness between the encoder disk and the rotor will appear in the 1–30 rpm low-speed range as jerking once or twice per revolution—it looks like “the motor has Parkinson’s,” but it is actually drift in the commutation angle zero offset. At the selection stage, confirm the encoder’s mounting reference surface, allowable axial and radial runout, and whether hollow-shaft cable routing will interfere with the encoder signal lines.

Cogging torque depends on the application scenario; it is not always best to pursue the lowest possible value. Force-controlled joints (such as collaborative robots and surgical robots) usually require cogging torque below 1% of rated torque, because the force disturbance introduced by cogging torque is difficult to fully compensate through control. But if you choose a “motor + reducer” architecture, the reducer itself has a certain filtering effect on torque ripple, so the priority of cogging torque can be appropriately relaxed. In direct-drive or quasi-direct-drive scenarios, however, cogging torque is transmitted to the load end almost without attenuation, so low-cogging solutions such as slotless cores or fractional-slot concentrated windings are worth the cost.

How to Choose a Brand: The Boundary Between Domestic and Imported Has Changed

Five years ago, the mid-to-high-end options for frameless torque motors almost by default pointed to overseas brands such as Kollmorgen. The reality of 2025–2026 is that, in terms of core performance metrics at similar sizes, leading domestic products have approached or caught up with overseas leaders. Comparing the Kinco FMC series and Leadshine GFM1 series with the Kollmorgen TBM series, main parameters such as torque range, stator diameter, and rated power are already in the same order of magnitude; in terms of price, domestic products are about 45% of imported products or even lower, and lead times are also significantly shorter.

But the boundary still exists. Overseas brands still have advantages in extreme performance (the peak torque ceiling for the same volume) and batch consistency, and yield gaps objectively exist in some high-end scenarios. Selection decisions can be tiered by scenario: if the joint’s operating conditions fall within your thermal calculations and voltage limits, and there are no stringent requirements for extreme burst performance, the advantages of leading domestic products in cost, lead time, and local support are substantial; if the application has hard constraints on the upper limit of torque density, long-term consistency, or extreme environments, overseas brands are still worth including in the comparison, but they no longer need to be regarded as the only option.

Back to the Starting Point of Selection

Selecting a hollow-shaft frameless torque motor is essentially not about “picking the model with the prettiest parameters,” but about translating the joint’s real operating conditions into torque, loss, and voltage requirements on the motor side, and then using your own cooling and assembly conditions to verify the manufacturer’s numbers. Leave 30% margin on continuous torque, recalculate thermal resistance based on your own housing, keep a 1.15× red line on bus voltage, and lock down coaxiality and encoder rigidity at the drawing stage—do these four things well, and you can basically avoid the major pitfalls in selection.

As for the brand, it is the result of selection, not the starting point. Work out the three calculations first, and let the constraints tell you the answer.

 